Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the slider domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/u483287566/domains/mygreatescapes.in/public_html/wp-includes/functions.php on line 6170

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the chaty domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/u483287566/domains/mygreatescapes.in/public_html/wp-includes/functions.php on line 6170

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the essential-blocks domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/u483287566/domains/mygreatescapes.in/public_html/wp-includes/functions.php on line 6170

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/u483287566/domains/mygreatescapes.in/public_html/wp-includes/functions.php on line 6170

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the essential-addons-for-elementor-lite domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/u483287566/domains/mygreatescapes.in/public_html/wp-includes/functions.php on line 6170

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the forminator domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/u483287566/domains/mygreatescapes.in/public_html/wp-includes/functions.php on line 6170

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the wpforms-lite domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/u483287566/domains/mygreatescapes.in/public_html/wp-includes/functions.php on line 6170

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the recycling-energy domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/u483287566/domains/mygreatescapes.in/public_html/wp-includes/functions.php on line 6170

Warning: Cannot modify header information - headers already sent by (output started at /home/u483287566/domains/mygreatescapes.in/public_html/wp-includes/functions.php:6170) in /home/u483287566/domains/mygreatescapes.in/public_html/wp-includes/feed-rss2.php on line 8
Neware Machines – SEMCO INFRATECH https://www.mygreatescapes.in Thu, 29 Feb 2024 11:03:05 +0000 en-US hourly 1 https://wordpress.org/?v=7.0 https://www.mygreatescapes.in/wp-content/uploads/2023/12/cropped-logo-4-32x32.jpeg Neware Machines – SEMCO INFRATECH https://www.mygreatescapes.in 32 32 EV Battery Testing System IGBT https://www.mygreatescapes.in/shop/neware-machines/ev-battery-testing-system-igbt/ https://www.mygreatescapes.in/shop/neware-machines/ev-battery-testing-system-igbt/#respond Tue, 27 Feb 2024 09:47:29 +0000 https://www.mygreatescapes.in/?post_type=product&p=4448 Power: 75kVA, 150kVA, 300kVA, 600kVA Voltage: 60V ~ 1000V Current: 100A - 1000A [wpforms id="246" title="true"]]]>
  • The new generation testing system with high voltage and high power output capability, is designed for the tests of battery pack.
  • Utilizes IGBT (Insulated Gate Bipolar Transistor) technology which is much different from traditional power devices and control methods. Stable and reliable testing control performance makes
  • The best testing system for EV battery and energy storage battery.
  • The key control circuit of IGBT system uses digital signal processor (DSP) as key digital circuit.
  • Based on TI’s C2000 platform, its abundant peripheral resources and high-speed digital computing capabilities enable it to meet the needs of data processing and system control.
  • ]]>
    https://www.mygreatescapes.in/shop/neware-machines/ev-battery-testing-system-igbt/feed/ 0
    Regenerative Testers 20V-1000V & 30A-800A https://www.mygreatescapes.in/shop/neware-machines/regenerative-testers-200v-750v-50a-500a/ https://www.mygreatescapes.in/shop/neware-machines/regenerative-testers-200v-750v-50a-500a/#respond Mon, 26 Feb 2024 07:51:33 +0000 https://www.mygreatescapes.in/?post_type=product&p=4380 Input power AC380V±10% 50/60±5Hz Power factor ≥99% (Full load) THDi ≤5% (Full load) Input resistance ≥1MΩ [wpforms id="246" title="true"]]]> Input power   66.7kW Input current   101.3A/Single Overall system 94%(Max)   94% ≤75dB   ≤75dB Voltage and current sampling   Four-wire connection (same port for charging and discharging) Power control module type   IGBT Input power wiring method   Three-phase-four wire system Power input protection   Anti-surge, anti-silos, anti over or under frequency, anti over or under voltage, anti-phase absence, etc. Functions and performances Voltage Output range Charge:0V~600V Discharge:10V~600V Min discharge voltage 10 Accuracy ±0.02% of FS Resolution 24bit Current Output range 0.25A~50A Accuracy (independent range) ±0.05 % of FS CV cut-off current 50mA Resolution 24bit Power Single channel output power 30kW Whole machine output power 60kW Time Current response time ≤5ms Current conversion time ≤10ms Min. step time 0.1s ]]> https://www.mygreatescapes.in/shop/neware-machines/regenerative-testers-200v-750v-50a-500a/feed/ 0 Battery Test System 100V 50A-500A with CAN https://www.mygreatescapes.in/shop/for-prismatic-cell/battery-charging-discharging-cabinet/battery-test-system-100v-50a-500a/ https://www.mygreatescapes.in/shop/for-prismatic-cell/battery-charging-discharging-cabinet/battery-test-system-100v-50a-500a/#respond Mon, 26 Feb 2024 07:34:15 +0000 https://www.mygreatescapes.in/?post_type=product&p=4369 Input power AC380V±15% 50/60±5Hz Power factor ≥99% (Full load) THDI ≤5% (Full load) Input resistance ≥1MΩ Input power 35.3KW [wpforms id="246" title="true"]]]> Input current   53.6A/Per Phase Overall system 90%(Max)   90% ≤65dB   ≤65dB Voltage and current sampling   Four-wire connection (different port for charging and discharging) Power control module type   MOSFET Input power wiring method   Three-phase-five wire system Power input protection   Anti-surge, anti-silos, anti over or under frequency, anti over or under voltage, anti-phase absence, etc. Functions and performances Voltage Output range Charge:0V~100V Discharge:3V~100V Min discharge voltage 3 Accuracy ±0.02% of FS Resolution 24bit Current Output range 1.5A~300A Accuracy (independent range) ±0.05 % of FS CV cut-off current 300mA Resolution 24bit ]]> https://www.mygreatescapes.in/shop/for-prismatic-cell/battery-charging-discharging-cabinet/battery-test-system-100v-50a-500a/feed/ 0 Temperature Test Chamber https://www.mygreatescapes.in/shop/other-products/testing-chambers/temperature-test-chamber/ https://www.mygreatescapes.in/shop/other-products/testing-chambers/temperature-test-chamber/#respond Mon, 26 Feb 2024 07:27:57 +0000 https://www.mygreatescapes.in/?post_type=product&p=4367 Product Name MHW-25-S: constant temperature test chamber 25: inner volume Application Constant temperature test for small pouch cell and coin cell [wpforms id="246" title="true"]]]> Sample limit ·        This test chamber is prohibited: Testing or storage of flammable, explosive, volatile materials;

    ·        Testing or storage of corrosive substance samples; Testing or storage of samples of strong electromagnetic emission;

    ·        Testing and storage of radioactive material samples;

    ·        Testing and storage of highly toxic substances;

    ·        Testing or storage of specimens that may produce above substances or objects during testing or storage. Volume and size Nominal internal

    volume 25L Inner size W280 mm×D250 mm×H360 mm Outer dimension W360 mm×D450 mm×H470 mm Net weight Around 40kg Performance Environmental conditions Environmental temperature: +25℃ Relative humidity≤85%

    no test samples in the test chamber (no load) Temperature

    range 0℃~60℃ Temperature fluctuation ≤1℃(No load, stable temperature) Temperature deviation ±2.0℃(No load, stable temperature) Heating time 25℃→60℃ ≤ 30 min Cooling time 25℃→0℃ ≤ 50 min Structure Insulation Outer wall material: high quality cold rolled steel plate, surface sprayed and painted; Envelope Inner wall material: stainless steel plate SUS304;

    Chamber insulation material: polyurethane foam (thickness of 50mm) Air conditioning Axial flow fan, evaporator, heater ]]> https://www.mygreatescapes.in/shop/other-products/testing-chambers/temperature-test-chamber/feed/ 0 Neware Cell Tester 5V 6A-30A 8CH-32CH https://www.mygreatescapes.in/shop/for-cylindrical-cell/cell-grading-machines-for-cylindrical-cell/battery-testing-equipment-5v-6a-12a/ https://www.mygreatescapes.in/shop/for-cylindrical-cell/cell-grading-machines-for-cylindrical-cell/battery-testing-equipment-5v-6a-12a/#respond Mon, 26 Feb 2024 06:45:21 +0000 https://www.mygreatescapes.in/?post_type=product&p=4341 Also Available in: Standalone
    Input AC AC 220V/110V ±10% / 50Hz
    Resolution AD:24bit;DA:16bit
    Input Impedance ≥1MΩ
    Input Power 425W
    [wpforms id="246" title="true"]]]>
    Channel Features Constant Current Source and Constant Voltage Source with

    Independent pairs of Closed-loop Structure  

     

     

    Voltage CV Output Range 25mv-5V Min Discharge

    Range 1.0V for universal holder, 1.5V for 2m cable Accuracy ± 0.05% of FS Stability ± 0.05% of FS  

     

     

    Current Per Channel Current Range Range 1: 0.5mA-100mA  Range 2: 100mA~3A

    Range 3: 3A-6A Accuracy ± 0.05% of FS CV cut-off current Range 1: 0.2mA Range 2: 6mA Range 3: 12mA Stability ± 0.05% of FS  

    Power Per Channel Output

    Power 30W Stability ± 0.1% of FS  

    Time Current Response

    Time <1ms (10% FS~90% FS) Working step time ≤ (365*24) hour/step, Time Format 00:00:00(h:  min: s, MS)  

    Data Record  

    Data record condition Min data record interval: 100mS Min voltage change:10mV Min current change: Range 1: 0.2mA, Range 2: 6mA, Range 3: 12mA Frequency 10Hz  

    Charge Charge Mode CC, CV, CCCV, CP End Condition Voltage, Current, Relative Time, Capacity, -△V  

    Discharge Discharge Mode CC, CV, CCCV, CP, CR End Condition Voltage, Current, Relative Time, Capacity, -△V  

    Pulse Charge CC, CP Discharge CC, CP Min Pulse Width 500ms Items Values   Pulse counts Up to 32 Automated Switch Automated switch from charge to discharge for each pulse Cut-off Condition Voltage, Time DCIR Calculated DCIR values available in BTSDA Cycle Max cycles 65535 Max Steps 254 Cycle nest 3 ]]> https://www.mygreatescapes.in/shop/for-cylindrical-cell/cell-grading-machines-for-cylindrical-cell/battery-testing-equipment-5v-6a-12a/feed/ 0 Battery Testing System 5V 50mA-100mA https://www.mygreatescapes.in/shop/neware-machines/battery-testing-system-5v-50ma-100ma/ https://www.mygreatescapes.in/shop/neware-machines/battery-testing-system-5v-50ma-100ma/#respond Mon, 26 Feb 2024 06:11:54 +0000 https://www.mygreatescapes.in/?post_type=product&p=4333 Items Values Input AC AC 220V/110V ±10% / 50Hz Input Power 40 Resolution AD:16bit;DA:16bit Input Resistance ≥1GΩ [wpforms id="246" title="true"]]]> Channel Features Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure  

     

    Voltage CV output range 10mV~5V Min discharge voltage -5V Accuracy ± 0.02% of FS Stability ± 0.02% of FS  

     

    Current Per Channel Current Range (Range 1: 0.2µA~0.1Ma) (Range 2: 0.1mA~1mA) (Range 3: 1mA~10mA) (Range 4:10mA~100mA) Accuracy ± 0.02% of FS CV cut-off current (Range 1: 0.1µA Range 2: 1µA) (Range 3: 10µA Range 4: 0.1mA) Stability ± 0.02% of FS  

    Power Output power/channel 0.5 W Stability ± 0.1% of FS  

    Time Current response time ≤1.5ms (10%FS~90%FS) Step Time Range ≤ (365*24) hour/step, Time Format 00:00:00(h: min: s:ms)  

    Data record  

    Data record conditions Min Time:10mS Min Voltage:5mV Min Current: (Range 1: 0.1µA) (Range 2: 1µA) (Range 3: 10µA) (Range 4: 0.1mA) Frequency 10 Hz  

    Charge Charge mode CC, CV, CCCV, CP End condition Voltage, Current, Relative Time, Capacity, -△V  

    Discharge Discharge mode CC, CP, CR, CCCV, CV (constant voltage) End condition Voltage, Current, Relative Time, Capacity  

     

     

    Pulse Mode Charge Constant Current, Constant Power Discharge Constant Current, Constant Power Min pulse width 500ms Pulse Cycle up to 32 Automated Switch Automated switch from charge to discharge for each pulse Cut-off condition Voltage, Test Time DCIR Calculate DCIR values via Neware BTSDA software  

    Cycle Max cycles 1~65535 Max steps 254 Cycle nest 3 ]]> https://www.mygreatescapes.in/shop/neware-machines/battery-testing-system-5v-50ma-100ma/feed/ 0 Battery Testing System 5V 30A-5V 200A https://www.mygreatescapes.in/shop/neware-machines/battery-testing-system-5v-30a-5v-200a/ https://www.mygreatescapes.in/shop/neware-machines/battery-testing-system-5v-30a-5v-200a/#respond Mon, 26 Feb 2024 06:04:32 +0000 https://www.mygreatescapes.in/?post_type=product&p=4331 Items Values Input AC AC 220V ±10% / 50Hz Input Power 2127 W Resolution AD:16bit;DA:16bit [wpforms id="246" title="true"]]]> Input Impedance ≥1MΩ  

     

    Voltage CV output range 0.025V~5V Min discharge voltage 30 Accuracy ± 0.1% of FS Stability ± 0.1% of FS  

     

    Current Output range/channel 0.15A~30A Accuracy ± 0.1% of FS CV cut-off current 0.06A Stability ± 0.1% of FS  

    Power Output power/channel 150 W Stability ± 0.2% of FS  

    Time Current response time Max rising time: 20ms Working step time ≤ (365*24) h/step, Time format-00:00:00.000(h: m: s:ms)  

    Data record Data record conditions Min data record interval:100ms Min voltage change:10mV Min current change:60mA Frequency 10Hz  

     

    Charge Charge mode Constant current, Constant voltage, Constant current and voltage, Constant power Cut-off condition Main channel:Voltage, Current, Δ Time, Capacity, -ΔV  

     

    Discharge Discharge mode Constant current, Constant power, Constant resistance, Support Customize constant current and voltage Cut-off condition Main channel:Voltage, Current, Δ Time, Capacity, -ΔV  

     

     

    Pulse Mode Charge Constant Current, Constant Power Discharge Constant Current, Constant Power Min pulse width 500ms Pulse Cycle up to 32 Charge and Discharge switch Auto Switched Cut-off condition Voltage, Time DCR Support DCR Calculation Based on User-Defined Record      

    Cycle Max cycles 1~65535 Max steps 254 Cycle nest 3

     

    ]]>
    https://www.mygreatescapes.in/shop/neware-machines/battery-testing-system-5v-30a-5v-200a/feed/ 0
    Neware Cell Tester 5V 100A 16CH https://www.mygreatescapes.in/shop/for-prismatic-cell/cell-grading-machines/battery-testing-system-5v-100a-5v-300a/ https://www.mygreatescapes.in/shop/for-prismatic-cell/cell-grading-machines/battery-testing-system-5v-100a-5v-300a/#respond Mon, 26 Feb 2024 05:48:17 +0000 https://www.mygreatescapes.in/?post_type=product&p=4329 Ranges: 5V 20A 64CH     5V120A-4CH    5V 200A 4CH 5V 30A 16CH     5V 200A 4CH    5V 500A 2CH 5V 30A 8CH     5V 300A 6CH    5V 800A 2CH 5V 60A 32CH     5V 300A 2CH    5V 800A 4CH 5V 60A 48CH     5V 300A 4CH 5V 60A 48CH     5V 200A 8CH 5V 100A 4CH     5V 200A 16CH 5V 100A 16CH     5V 200A 16CH 5V100A-32CH     5V 200A 24CH [wpforms id="246" title="true"]]]> Input Impedance ≥1MΩ  

     

    Voltage CV output range 0.025V~5V Min discharge voltage 2V Accuracy ± 0.05% of FS Stability ± 0.1% of FS  

     

    Current Output range/channel 1A~200A Accuracy ± 0.1% of FS CV cut-off current 0.4A Stability ± 0.1% of FS  

    Power Output power/channel 1000 W Stability ± 0.2% of FS  

    Time Current response time Max rising time: 20ms Working step time ≤(365*24)h/step, Time format-00:00:00.000(h:m:s:ms)  

    Data record Data record conditions Min data record interval:100ms Min voltage change:10mV Min current change:400mA Frequency 10Hz  

     

    Charge Charge mode Constant current, Constant voltage, Constant current and voltage, Constant power Cut-off condition Main channel:Voltage, Current, Δ Time, Capacity, -ΔV  

     

    Discharge Discharge mode Constant current, Constant power, Constant resistance, Support Customize constant current and voltage Cut-off condition Main channel:Voltage, Current, Δ Time, Capacity, -ΔV  

     

     

    Pulse Mod

    e Charge Constant Current, Constant Power Discharge Constant Current, Constant Power Min pulse width 500ms Pulse Cycle up to 32 Charge and Discharge switch Auto Switched Cut-off condition Voltage, Time DCR Support DCR Calculation Based on User-Defined Record Parallel Mode Maximum support 4 channel parallel ,Pulse and Simulation are not available after parallel mode ]]> https://www.mygreatescapes.in/shop/for-prismatic-cell/cell-grading-machines/battery-testing-system-5v-100a-5v-300a/feed/ 0